Intelligent monitor at the end of sprinkler system
- The intelligent monitor at the end of the sprinkler system adopts an integrated process design, with internal integrated electronic circuits, microprocessors, integrated temperature and pressure sensors, batteries and wireless transmission modules; among them, the structural design is compatible with the mechanical pressure gauge interface at the end of the traditional sprinkler system , It is convenient for the reconstruction and construction of the existing system, which is installed and operated; the detector regularly monitors the pressure value and temperature value at the end of the sprinkler system pipe network, automatically judges the water pressure and water temperature status, and sends an alarm message when the set threshold is exceeded. The monitored information is uploaded at a fixed time every day, installed locally, and supports magnetic wake-up mode.
-
Product introduction
The intelligent monitor at the end of the sprinkler system adopts an integrated process design, with an internal integrated electronic circuit, a microprocessor, a temperature and pressure integrated sensor, a battery and a wireless transmission module; , The structural design is compatible with the mechanical pressure gauge interface at the end of the traditional sprinkler system, which is convenient for the reconstruction and construction of the existing system, which is installed and run; the detector regularly monitors the pressure value and temperature value at the end of the sprinkler system pipe network, automatically Judging the water pressure and water temperature status, sending an alarm message when the threshold is exceeded, uploading the monitored information at a fixed time every day, local installation, and supporting magnetic wake-up mode.
Related parameters
stress test | 0~1.6MPa 1%FS |
Water temperature test | -30℃~ 70C |
Communication method | NB-loT |
Work mode | Periodic upload and alarm upload |
Collection period | default 3 minutes |
Upload cycle | 12 minutes by default |
Alarm period | default 6 minutes |
low pressure alarm value | default 0.15MPa |
High voltage alarm value | default 0.7MPa |
Battery life | ≥10 years (normal mode) |
Wake-up method | Magnetic induction |
Working temperature | -20°℃ ~60°℃ |
Installation method | In-place installation (threaded) |
-